Home > Informix Error > Informix Error 25582

Informix Error 25582


also when i tried to search about the specific error (-25582) i found nothing on the web. but this not happens every day. A system call has failed. Powered by vBulletinCopyright ©2000 - 2016, Jelsoft Enterprises Ltd.Forum Answers by - Gio~Logist - Vbulletin Solutions & Services Home Register New Posts Advertising Archive Privacy Statement Sitemap Top Hosting and Cloud http://offsethq.com/informix-error/informix-error-code-25582.html

JackLiUnable to connect to SQL Server on azure VM due to an extra NSG applied to subnet September 18, 2016If you need to open up your SQL Server on an Azure We keep getting frequent Informix freezes on our server caused by the error numbers 25572,25574, 27001. If you do not have a valid user ID on the server computer, see your system administrator. It can also be due to some changes in the following files: /etc/services the informix sqlhosts file /etc/hosts file do all relevant parameters and values match correctly ? http://www-01.ibm.com/support/docview.wss?uid=swg21633445

Network Connection Is Broken Informix

System error = 104. 08:19:54 listener-thread: err = -25580: oserr = 104: errstr = : System error occurred in network function. Read 2 Feb 11 - DBTAs - Informix 11.7 Flexible Grid Provides a Different Way of Looking at Database Servers... As the finderr output above points out, you should first make sure your connection information is correct. Read these documents for further help resolving 25582 errors: http://www.ibm.com/support/docview.wss?uid=swg21468244 http://www.ibm.com/support/docview.wss?uid=swg21576544 Document information More support for: Informix Servers Software version: 10.0, 11.1, 11.5, 11.7, 11.70, 12.1 Operating system(s): AIX, HP-UX, Linux,

Read 2 Feb 12 - developerWorks - Loading data with the IBM Informix TimeSeries Plug-in for Data Studio... Informix Dynamic Server Version 7.31UD4 SCO unix openserver 5.0.6 Thank you for help!!! Re: listener-thread Network error (views: 798)Art Kagel -- Wednesday, 11 August 2010, at 2:09 p.m. [ View Thread ] [ Post Response ] [ Return to Index ] [ Read Prev The instance was working fine and out of nowhere i could see the following message on Informix log: "listener-thread: err=-25582: oserr=0: errstr=: Network connection is broken" The same message appeared for

Whats New in 12.10 Certified for Informix 11.10, 11.50, 11.70 and 12.10 Finderr -25582 Network connection is broken. Listener-thread: Err = -956 What version of informix are you running? On NT check username, and IXUSERS group. 13:34:40 listener-thread: err = -25571: oserr = 0: errstr = : Cannot create an user thread. Visit Website Read 22 Mar 12 - developerWorks - Optimizing Informix database access...

When you encounter this error on the database server side, it is a warning that a network I/O error is detected while the database server is accepting a connection request from System error = 104. 08:22:29 listener-thread: err = -25580: oserr = 104: errstr = : System error occurred in network function. How does it compare to your number of connections? Read 14 Mar 12 - BernieSpang.com - International Informix User Group set to meet in San Diego...

Listener-thread: Err = -956

Read 12 Oct 10 - Database Trends and Applications - Informix 11.7: The Beginning of the Next Decade of IBM Informix... http://www.dbforums.com/showthread.php?1676087-listener-thread-err-25582-oserr-0-errstr-Network-connection-is-broken If this error occurs frequently on a database server that runs on a host with multiple processors, you might want to tune the database server by increasing the number of poll Network Connection Is Broken Informix Thank you ! Regards Ragha Originally posted by rkeshava Hi, listener-thread: err = -25580: oserr = 232: errstr = : System error occurred in network function.

So, I scanned the main server looking for viruses using Trend Micro Server Protect, it didn´t find anything (0 viruses and spywares). http://offsethq.com/informix-error/informix-error-214.html I assume this is the main connection. But "09:27:01 WARNING: mt_aio_wait: errno == EINVAL 09:27:01 listener-thread: err = -951: oserr = 2: errstr = ccx99: Incorrect password or user ccx99 is not known on the database server. The time now is 15:25.

The maximum no of concurrent users is 102. In general, each Informix error contains the following information: • The Informix Error Code or Informix Error status • The message text. An error in the application can produce this message. navigate here System error = 104. 08:22:29 listener-thread: err = -25580: oserr = 104: errstr = : System error occurred in network function.

Read 1 Mar 12 - IBM Data Management - Running Informix on Solid-State Drives.Speed Up Database Access... Forum New Posts Today's Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links View Site Leaders dBforums Database Server Software Informix listener-thread: err = -25582: oserr = 0: errstr = Share a link to this question via email, Google+, Twitter, or Facebook.

Have we attempted to experimentally confirm gravitational time dilation?

Output from "finderr 27001": -27001 Read error occurred during connection attempt. Also note that some threads are successfully connecting to and retrieve information from the Informix database whereas others are not. Check for the wrong connection name. Required fields are marked *Comment Name * Email * Website Polls Which Relational Database Management System Do you Like?

This error might indicate that the database server has terminated, or a problem might exist on the network itself. I am the administrator ;-). -25582 Network connection is broken. But we haven't I/O network error. his comment is here Or possibly a client terminated its connection attempt before the connection is completely established.

Check that the network is functioning and that the server is still running. our online.log says: ... 13:34:39 listener-thread: err = -25571: oserr = 0: errstr = : Cannot create an user thread. Check that the servicename column of your sqlhosts file is correct. We are looking for Network issues but we could not find anything strange..more over this issue is happening ramdomly.

What os platform are you on? Here is a screenshot of that setting.  It allows you to configure various things like auto backup, patching or... more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science Here is the architecture of my application: 1.

Shall I force them out, so that I can maintain the concurrent users numbers within the limit. Anny I assume you have only one CPU? If you are using Enterprise Replication (ER) you might receive an error similar to the following in the Informix message log: 14:45:02 CDR NIF ASF SEND failed asfcode -25580 oserr 119 This is the version that we have: IBM Informix Dynamic Server Version 11.70.FC3X5GE -- On-Line (Prim) -- Up 03:05:04 -- 15198756 Kbytes IBM Informix Growth Edition I will appreciate any comments

I can also see you have a patched version on your primary server, do you have the same patched version on the secondary ? Read 19 May 10 - ZDNet - IBM software in your home? listener-thread: err = -25582: oserr = 0: errstr = : Network connection is broken. Here's Why Members Love Tek-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More...